AS200 Alignment Sensor GENERAL (1.7.1 Rev. A - January 2019) - Software Release Date: January 2019 The release notes and related product documentation might have been updated since the release date. You can view the latest release notes and documentation, including the localized editions, at the Cognex support site at https://support.cognex.com/en/downloads/alignment-sensor.   INSTALLATION AND CONFIGURATION (1.7.1 Rev. A) - For installation information, see the "AS200 Alignment Sensor Quick Start Guide," accessible from the Help button. - For the detailed configuration information, see the "AS200 Alignment Sensor User Guide," available at the Cognex support site (https://support.cognex.com/en/downloads/alignment-sensor).   ================================= NEW FEATURES (1.7.1 - January 2019) - Introduced error codes. The return status of a command can now be < 0. Error codes are listed in the Communication supplement document. - If system is calibrated, a feature's training position will automatically be its Golden Pose. "TA" command will override, if required. - Added commands to set/get Golden Feature Pose in Home2D, Camera2D or Raw2D.Can be overridden with "TA" command. - Added command to get current feature position in Home2D, Camera2D or Raw2D. - The timing information in the log now has ms resolution. - Incoming and outgoing messages have different background grey values now. - A crosshair in the center of fov can now be shown in live mode. - Added continuous trigger mode on Feature Setup page. - Added image playback mode on Feature setup page. - New GUI design (icons). ================================= KNOWN Issues (1.7.1 - January 2019) - Occasionly it may occur that the crosshair indicating the Golden Feature Pose is not displayed when the "XA" command has been executed. ================================= NEW FEATURES (1.5.0 - August 2018) - Support of the camera's Strobe output usage. It can be configured on the Sensor's Advanced setup page. - More detailed calibration information. - Support of 9-point Custom Calibration (requires X/Y moving capability of motion system). - More detailed timing information. The time stamps in the log now have a resolution of ms. Time used by vision tools are shown on display. - Log of incoming and outgoing messages now have different background grey tone for better capability to be distinguished. ================================= KNOWN Issues (1.5.0 - August 2018) - On some systems there may be a problem with Acrobat Reader DC opening the help file using the Help (“?”) button on the main page. The Acrobat process will be started but the window doesn’t show up. The Acrobat process must be killed in this case. WORKAROUND: Set Edge Browser as default program for .pdf files. KNOWN ISSUES (1.0.0 Rev. B - July 2018) - If a camera does not have an internal light connected, acquisition with this camera will hang when the “Light Enable” checkbox is unchecked in the Exposure Settings for this camera. Always keep this checkbox checked (default setting) if there is no light connected to a camera. (CR# 432) KNOWN ISSUES (1.0.0 Rev. A) - The AS200 Alignment Sensor software requires Microsoft .NET Framework 3.5 SP1, which is not pre-installed to Microsoft Windows 10. To install Microsoft Framework 3.5 SP1, you must have internet access. If the AS200 Alignment Sensor software installer fails to detect Microsoft .NET Framework 3.5 SP1, it will attempt to download and install it. (CR# 410)